The site plan shall be prepared in a legible scale, preferably of 1:200 or 1:500 with plan oriented in North-South direction. The site plan shall contain the following details, namely: -
(a) All site boundaries with dimensions, by superimposing the survey sketch issued by Revenue Department, the sketch attached to the title document and the survey sketch prepared by conducting physical survey of plot using Total Intelligent Station. At least 3 boundary points of all the sketches should match when superimposed. The innermost
boundaries of the plot derived by superimposing all the sketches shall be considered as the boundary of the plot and the area of the plot within such boundary shall be considered as the extent of the plot as existing at site;
Extent of plot, which shall be lesser of the extent as per document, revenue sketch or as existing at site (as derived from clause ‘a’ above);
(c) All roads abutting the plot with existing width, proposed width and centerline of the road. The road widening line and building line, if any, shall be marked on the plot, if applicable, showing the portion of the plot required for road widening; (in case of varying width of the road, the survey of the road using total intelligent station shall be attached showing the average width of the road as per the provisions of the ZR)
(d) Portion of Plot to be reserved for Park and Open Spaces and Civic Amenities, if required as per Section 17 of Karnataka Town and Country Planning Act, 1961
(e) Land use as per Master Plan and the permitted land use as per Zonal Regulations;
(f) Contours of the plot at 1m intervals along with the levels of the adjoining plots and of the abutting roads;
(g) Location with dimensions and extent of Kharab lands within the plot;
(h) Location of roads of the Master Plan passing through the plot, if any;
(i) Location of all natural features such as trees, water bodies (including wells, ponds, storm water drains, etc.) quarries including buffer area, etc.;
(j) Location of city level sewerage and H.T. lines passing through the plot including buffer area;
(k) Eligibility for relaxation of setbacks as per Zonal Regulations;
The following additional details shall be incorporated in the site plan;
(a) Building footprint (portion of the floor plan of the building projecting above the ground) for Ground coverage and setbacks and the projections in the upper floors, beyond the footprint area (in dotted line).
(b) Details of constructions provided in the setback area of the plot, including ramps (along with slope of ramp), driveway and also the parking spaces provided in the open yard.
(c) Details of the over ground and underground services provided such as water supply, sewerage, power supply and telecommunication system and details of the rain water harvesting system (pipelines, cables, chambers, manholes, transformer and generator yard / substation, STP and pump room, solid waste management plant, etc.)
(d) Entry and Exit to plot with gate and entry / exit arch details.
(e) Levels contiguous to the building and the boundaries / corners of the plot.
(f) Details for identification of neighbouring properties.
(g) Portion of the plot earmarked as unpaved areas as per clause and chapter wherever applicable.
(c) Index of drawing as specified in Appendix-III.