(20) IS 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part1Selection of type of wall.
(21) IS 14458 (Part 2): 1997 Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast walls
(22) IS 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3Construction of dry stone walls
(23) IS 14496 (Part 2): 1998 Guidelines for preparation of landslide – Hazard zonation maps in mountainous terrains: Part 2 Macro-zonation.
Note: Whenever an Indian Standard including those referred in the National Building Code or the National Building Code is referred, the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code.
7.1.2 Structural Design Basis Report (SDBR).- In compliance of the design with the above Indian Standard, the Structural Engineer on Record will submit a structural design basis report in the Performa attached herewith covering the essential safety requirements specified in the Standard.
The ‘Structural Design Basis Report (SDBR)’consists of four parts
Part 1: General Information/ Data
Part 2: Load Bearing Masonry Buildings
Part 3: Reinforced Concrete Buildings
Part 4: Steel Buildings
(a) Drawings and Documents to be submitted for approval of appropriate authorities shall include SDBR as detailed below:
Part 1: Completed
Part 2: (if applicable) – completed
Part 3: (if applicable) – undertaking that completed Part 3 will be submitted before commencement of construction.
Part 4: (if applicable) – undertaking that completed Part 4 will be submitted before commencement of construction.
(b) SDBR as detailed below shall be submitted to the appropriate authority as soon as design of foundation is completed, but not later than one month prior to commencement of construction.
Part 1: Completed
Part-2, Part-3 or Part-4: (if applicable) Completed
7.1.3 Seismic strengthening/retrofitting.- Prior to seismic strengthening/retrofitting of any existing structure, evaluation of the existing structure as regards structural vulnerability in the specified wind/seismic hazard zone shall be carried out by the SER. If as per the evaluation of the SER the seismic resistance is assessed to be less than the specified minimum seismic resistance as given in the note below, action will be initiated to carry out the upgrading of the seismic resistance of the building as per applicable standard guidelines.
Note:
(1). For masonry buildings reference shall be made to IS 4326 and IS 13935
(2). For concrete buildings and structures reference shall be made to IS15988: 2013 Seismic
evaluation and strengthening of existing RCC buildings.
7.1.4 Buildings with Soft Storey.- In case buildings with a flexible storeys, such as the ground storey consisting of open spaces for parking that is ‘Stilt buildings’ or any other storey with open halls, special arrangements are to be made to increase the lateral strength and stiffness of the soft/open storey such as Steel bracing / Shear walls / Brick infill’s between columns. Dynamic analysis of building is to be carried out including the strength and stiffness effects of infills and inelastic deformations in the members, particularly, those in the soft storey, and the structural members are to be designed accordingly.
Alternatively, the following design criteria are to be adopted after carrying out the earthquake analysis, neglecting the effect of infill walls in other storeys:
(a). The columns and beams of the soft storey shall be designed for 2.5 times the storey shears and moments, calculated under seismic loads specified in the other relevant clauses; or,
(b). Besides the columns designed and detailed for the calculated storey shears and moments, shear walls shall be placed symmetrically in both directions of the building as far away from the Centre of the building as feasible; to be designed exclusively for 1.5 times the lateral storey shear force calculated as before. For details of design and provisions, IS 1893, Part 1 shall be referred.